£0.00
- Items (0)
Gira KNX heating actuator, 6-gang with controller

Gira KNX heating actuator, 6-gang with controller

  code:GIR212900
  • Offers Available
  • Free UK Delivery when you spend £500.00
£225.83
( £271.00 inc. VAT)
Item in StockUsually dispatched within 24 - 48 hours
Add to Bag
This product has been added to your basket...
  • Continue Shopping
  • Checkout

Features

  • Heating actuator with integrated room temperature controller for switching electrothermic valve drives for heating or cooling ceilings.

Valve outputs

  • Switching operation or PWM operation.
  • Servos with the characteristic "de-energised open" or "de-energised closed" can be controlled.
  • Servos can be activated with rated voltage 24 V or 230 V.
  • Building site operation: Outputs can be operated manually without bus voltage with operating voltage only.
  • Feedback in manual actuation and in bus operation.
  • Blocking of individual outputs manually or with bus.
  • Overload protected, short-circuit protected, errors indicated with LED.
  • Protection against jammed valves.
  • Forced setting.
  • Various setpoint values for forced setting or emergency mode in case of bus failure for the summer and winter.
  • Cyclical monitoring of the input signals can be parameterised.
  • Feedback via bus e.g. for valve voltage failure, overload, and short circuit.
  • Switching the heating circuit pump depending on the valve conditions.
  • Group feedback of the closed servos.
  • Power-saving mode for reducing the energy consumption of the heating actuator. Application for periods (e.g. summer) when heat is not required for heating.
  • Activation of servo with "first open function" during start-up.
  • Fast commissioning thanks to global setting of the channels.
  • Cascading of several heating actuators.
  • Resetting error messages via bus.
  • Heating requirements control.
  • Elapsed operating time meter per channel.

Room Temperature Controller

  • 6 independent controllers.
  • Control via individual communication objects for inputs and outputs.
  • Optional internal group communication for individual assignment of the controller outputs to the output channels of the actuator.
  • Operating modes: Comfort, standby, night, and frost/heat protection.
  • Each operating mode can be assigned its own setpoint temperature values.
  • Configuration of the temperature setpoints either relative (derived from basic setpoint) or absolute (independent setpoint temperatures for each operating mode).
  • Comfort extension using the presence button, duration parameterisable.
  • Operating mode changeover using 1-byte objects in accordance with the KNX specification or by up to 4 individual 1-bit objects.
  • Configurable status feedback.
  • Frost/heat protection changeover via window status or via frost protection automatic function.
  • "Heating", "Cooling" and "Heating and Cooling" operating modes respectively with or without additional stage. The temperature setpoints for the additional stage are derived by a parameterisable stage interval from the basic stage values.
  • Various control types can be configured according to the heating or cooling level: PI control (constant or switching PWM) or 2-point control (switching).
  • Control parameters for PI controller (if desired: proportional area, readjustment time) and 2-point controller (hysteresis) can be set.
  • Automatic and object-oriented switching between "Heating" and "Cooling".
  • Room temperature measurement via up to two external KNX temperature sensors. Comparison of the temperature values is possible and the measured value generation of the external sensors can be parameterised. Query time of the externally received temperature values can be set.
  • The actual and setpoint temperatures can be output to the bus (incl. cyclical) after a parameterisable deviation.
  • Separate or joint corrected variable output in heating or cooling mode. This results in one or two corrected variable objects per stage.
  • Normal or inverted corrected variable output.
  • Automatic transmission and cycle time for corrected variable output can be parameterised.
  • Variable limitation is possible.
  • Floor temperature limitation possible in heating mode.
  • Setpoint temperature limitation possible in cooling mode.

Technical data

Rated voltage:AC 110 to 230 V, 50/60 Hz

Standby: max. 0.4 W

Power loss: max. 1 W

Outputs/controller: 6

Contact type: Triac

Switching voltage: AC 24/230 V, 50/60 Hz

Switching current: 5 to 160 mA

Switch-on current: max. 1.5 A (2 s)

Number of drives per output
AC 230 V drives: 4
AC 24 V drives: 2

Connections: max. 4 mm²

Return Policy

Where the customer rejects the Goods as not being in accordance with the customer's requirement, the company shall reserve the right to refund all or part of the original invoiced amount. When the customer sends an item back to the company (or, when the company arranges for collecting from the customer), the company will process the returned item then notify the customer via e-mail of the refund. The refund shall be in the same form of payment originally used for purchase within three weeks of the company receiving the returned item(s). Items returned within the seven-day cooling off period. All returned items must be accompanied with a return form (click here) and an RMA number, please complete and return your return form by e-mail and we will confirm your returns number -

 

  • By law, customers located in the European Union have the right to withdraw from the purchase of an item within seven working days of the day after the date on which the item is delivered.
  • Where you are withdrawing from your purchase within the seven working day cooling-off period, and there has been no error on our part, we will refund the cost of the item.
  • Where the customer is withdrawing from the purchase between seven and 30 days after delivery, and there has been no error on the part of the company, the company will refund only the cost of the item as invoiced less a standard 25% charge per item for restocking.
  • The company will not refund the cost of delivery or other services provided to the customer in connection with the purchase.
  • Where we collect an item from you, we reserve the right to recover the costs of collection from you. Our refunds policy does not affect your statutory rights.
Be the first to review Gira KNX heating actuator, 6-gang with controller. Write a review ›