  • The controller unit switches and dims electrical devices that have a 1-10 V interface.
  • Five device configurations can be selected. This leads to the assignment of four individually-controllable dimming channels to the switching outputs (e.g. four dimming channels are assigned to one switching relay to control a RGBW light).
  • Relay outputs that are not associated with a dimming channel can be used as freely-acting switching actuator channel.
  • Reactions in case of bus voltage failure and restoration can be set following an ETS programming process.
  • Manual actution of outputs independent of the bus with mechanical switching position indication.
  • Delay for actively transmitted feedback messages following bus voltage recovery.
  • Logical linking function configurable per channel.
  • Up to three central switching functions for the joint control of all dimming and switching channels.
  • Switch-on times of the relay outputs can be recorded and evaluated by the elapsedoperating time meter.
  • Group feedback of all switching conditions possible.

Dimming channels

  • Four individually-controllable dimming channels.
  • Feedback on switching condition and brightness value.
  • Dimmable brightness range can be set.
  • Dimming behaviour and dimming characteristics can be parameterised.
  • Soft switch-on and soft switch-off function
  • Block function or forced setting function can be parameterised.
  • Time functions (switch-on delay, switch-off delay, staircase light function). With the staircase light function, the reaction at the end of the switch-on time can be configured.
  • Inclusion of a dimming channel in up to ten scenes is possible.
  • The burning-in function allows for the start-up of new fluorescent lamps prescribed by lighting manufacturers.

Switching actuator operation (optional)

  • Independent switching of switch outputs A2 to A4.
  • NO contact or NC contact operation.
  • Feedback from the switching condition.
  • Block function or forced setting function can be parameterised.
  • Time functions (switch-on, switch-off delay, staircase light function - also with advance warning function).
  • Can be integrated in the light scenes. Up to ten internal scenes per switching output are programmable.
  • Cyclical monitoring of incoming switching telegram is configurable.

Technical data

Number: 4
Contact: 1 x zero-voltage NO contact each, flip-flop
Control outputs
Control voltage:1 to 10 V
Control current per output: max. 100 mA
Cable length: max. 500 m at 0.5 mm²
Switching outputs
Switching voltage: AC 250/400 V
Switching current 230 V AC1: 16 A
Switching current 230 V AC3: 10 A
Switching current 400 V AC1: 10 A
Switching current 400 V AC3: 6 A
Fluorescent lamps: 16 AX
Lamp loads
Light bulbs: 3680 W
HV halogen lamps: 3680 W
Wound transformer: 2000 VA
Gira Tronic transformer: 2500 W
Fluorescent lamps T5/T8
Uncompensated: 3680 W
Parallel-compensated: 2500 W/200 µF
Duo-circuit: 3680 W/200 µF
Compact fluorescent lamps
Uncompensated: 3680 W
Parallel-compensated: 2500 W/200 µF
Mercury-vapour lamps
Uncompensated: 3680 W
Parallel-compensated: 3680 W/200 µF
Ambient temperature: -5 °C to +45 °C
KNX: Connection and junction terminal
1 – 10 V: Screw terminals
Load: Screw terminals
Connections: max. 4 mm²
Dimensions: 4 HP

Return Policy

Where the customer rejects the Goods as not being in accordance with the customer's requirement, the company shall reserve the right to refund all or part of the original invoiced amount. When the customer sends an item back to the company (or, when the company arranges for collecting from the customer), the company will process the returned item then notify the customer via e-mail of the refund. The refund shall be in the same form of payment originally used for purchase within three weeks of the company receiving the returned item(s). Items returned within the seven-day cooling off period. All returned items must be accompanied with a return form (click here) and an RMA number, please complete and return your return form by e-mail and we will confirm your returns number -


  • By law, customers located in the European Union have the right to withdraw from the purchase of an item within seven working days of the day after the date on which the item is delivered.
  • Where you are withdrawing from your purchase within the seven working day cooling-off period, and there has been no error on our part, we will refund the cost of the item.
  • Where the customer is withdrawing from the purchase between seven and 30 days after delivery, and there has been no error on the part of the company, the company will refund only the cost of the item as invoiced less a standard 25% charge per item for restocking.
  • The company will not refund the cost of delivery or other services provided to the customer in connection with the purchase.
  • Where we collect an item from you, we reserve the right to recover the costs of collection from you. Our refunds policy does not affect your statutory rights.
Be the first to review Gira KNX control unit 1 – 10 V, 4-gang with manual actuation. Write a review ›